Grow tent fan size calculator

Results update as you type. The page URL keeps your inputs, so you can bookmark or share them.

Tent (ft)
Air path
Heat

How this works

Base CFM = tent volume ÷ exchange minutes. Losses: carbon filter +25%, flexible duct +5% per 5 ft, each 90° bend +10%. Heat check: CFM ≥ watts × 3.412 ÷ (1.08 × ΔT°F). We take the larger of the two and add headroom. Fan class: ≤190 CFM → 4″, ≤400 → 6″, ≤750 → 8″, ≤1,200 → 10″.

Then compare fans in our best inline fan for a grow tent guide.

FAQ

What size inline fan do I need for a 4x4 grow tent?

A 4×4×6.7 ft tent is about 107 ft³. With one air exchange per minute, a carbon filter, 8 ft of duct, one bend and 25% headroom you need roughly 200 CFM, so a 6-inch fan run on a speed controller is the usual choice.

How much does a carbon filter reduce airflow?

Plan on about 25% more fan capacity with a carbon filter. Each 90° bend adds roughly 10% and every 5 ft of flexible duct about 5%.

Should I oversize my exhaust fan?

Yes, modestly. A fan running at 60–70% on a controller is quieter and has headroom for hot days.